PRODUCTS → PVC Cables → Harmonized PVC

Single core wires


Connecting single core cable H07V-U (Ye)

Construction:
- solid bare copper core
- PVC insulated core

Nominal voltage: 450/750 V
Temperature: -5°C to +70°C

Application: To be installed in dry areas in pipes under the wall plaster or above wall plasters without pipes for suitable insulators. Can not be installed freely into the wall plaster or for outdoor use.

Connecting single core cable H05V-U (YSe)

Construction:
- solid bare copper core
- PVC insulated core

Nominal voltage: 300/500 V
Temperature: -5°C to +70°C

Application:To be installed in dry areas in pipes under the wall plaster or above wall plasters without pipes for suitable insulators. Can not be installed freely into the wall plaster or for outdoor use.

Fine stranded single core cable H07V-K (Yf)

Construction:
- fine stranded bare copper core
- PVC insulated core

Nominal voltage: 450/750 V
Temperature: -5°C to +70°C

Application: To be installed in dry areas in pipes under the wall plaster or above wall plasters without pipes for suitable insulators. Can not be installed freely into the wall plaster or for outdoor use.

Fine stranded single core cable H05V-K (YSf)

Construction:
- fine stranded bare copper core
- PVC insulated core

Nominal voltage: 300/500 V
Temperature: -5°C to +70°C

Application:To be installed in dry areas in pipes under the wall plaster or above wall plasters without pipes for suitable insulators. Can not be installed freely into the wall plaster or for outdoor use.


Multiple core wires

 

Storage electro-installation cable AT-N05VV-U (YM)

Construction:
- solid bare single copper core
- PVC insulated core
- wires braided together
- outer sheath of PVC

Nominal voltage: 300/500 V
Temperature: -5°C to +70°C

Application: Usable in dry and damp environments, inside wall plaster, above it or below it.

Flexible cable H05VV-F (YMM-J)

Construction:
- fine stranded bare copper core
- PVC insulated core
- wires braided together
- outer sheath of PVC
- dual-pole cable added with wire cover

Nominal voltage: 300/500 V
Temperature: -5°C to +70°C

Application: Usable in dry environments to connect light, movable appliances with small mechanical stress, as well as in iluminating objects, radios and televisions.

Flexibile cable H05VV-F (YMM-O)

Construction:
- fine stranded bare copper core
- PVC insulated core
- wires braided together
- outer sheath of PVC
- dual-pole cable added with wire cover

Nominal voltage: 300/500 V
Temperature: -5°C to +70°C

Application: Usable in dry environments to connect light, movable appliances with small mechanical stress, as well as in iluminating objects, radios and televisions.

Flat cable H03VVH2-F (YMLfl)

Construction:
- fine stranded bare copper core
- PVC insulated core
- wires braided together
- outer sheath of PVC in flat or round shape

Nominal voltage: 300/300 V
Temperature: -5°C to +70°C

Application:Usable in dry environments to connect light, movable appliances with small mechanical stress, as well as in iluminating objects, radios and televisions.

Round cable H03VV-F (YML-O)

Construction:
- fine stranded bare copper core
- PVC insulated core
- wires braided together
- outer sheath of PVC in flat or round shape

Nominal voltage: 300/300 V
Temperature: -5°C to +70°C

Application: Usable in dry environments to connect light, movable appliances with small mechanical stress, as well as in iluminating objects, radios and televisions.

Round cable H03VV-F (YML-J)

Construction:
- fine stranded bare copper core
- PVC insulated core
- outer sheath of PVC in flat or round shape

Nominal voltage: 300/300 V
Temperature: -5°C to +70°C

Application: Usable in dry environments to connect light, movable appliances with small mechanical stress, as well as in iluminating objects, radios and televisions.